12
7/32” (5.69 mm)
MONOCONDUCTOR
1N22
PROPERTIES: Cable Diameter: Minimum Shave Diameter: Cable Stretch Coefficient ELECTRICAL: Maximum Conductor Voltage Conductor AWG Rating Minimum Insulation Resistance Armor Electrical Resistance: MECHANICAL: Cable Breaking Strength: Ends Fixed: Ends Free: Maximum Suggested Working Tension: Number and Size of Wires: Inner Armor Outer Armor Average Wire Breaking Strength: Inner Armor Outer Armor
Cable Type Temp Rating °F °C 300 149 420 216
0.224” +0.005” - 0.002” 13” 2.5 ft/Kft/Klbs
(5.69mm + 0.13mm -0.05mm) (33 cm) (2.80 m/Km/5KN)
1,200 VDC 16 1,500 MegaΩ/Kft @ 500VDC 4.4 Ω/Kft
(457 MegaΩ/Km @ 500VDC) (14.4 Ω/Km)
5,200 lbs 3,900 lbs 2,600 lbs 12 x 0.0310” 18 x 0.0310” 204 lbs 204 lbs
(23.0 KN) (17.3 KN) (11.6 KN) (0.787 mm) (0.787 mm) (0.91 KN) (0.91 KN)
Nominal Nominal
Core Description Cable Weight Plastic Type Copper Res Cap. O.D. in in Spec. Insulation Thickness Cons truction Typical Typical Each Air H2O Gravity in in Ω /Kft pf/ft in lbs/Kft mm mm Ω/Km pf/m mm Kg/Km 1N22PP Poly 0.0245 19x0.0119 4.1 58 0.108 94 79 6.48 0.622 19x0.302 13.5 190 2.743 140 118 1N22PXZ Camtane 0.0130 19x0.0119 4.1 59 0.085 95 80 6.56 0.330 19x0.302 13.5 194 2.159 141 119 Tefzel 0.0115 0.108 0.292 2.743 1N22PZ 500 Tefzel 0.0245 19x0.0119 4.1 68 0.108 97 82 6.67 260 0.622 19x0.302 13.5 223 2.743 144 119 1N22PTZ 500 Teflon 0.0130 19x0.0119 4.1 58 0.085 97 82 6.69 260 0.330 19x0.302 13.5 190 2.159 144 119 Tefzel 0.0115 0.108 0.292 2.743 1N22PA 550 PFA 0.0245 19x0.0119 4.1 54 0.108 97 83 6.73 288 0.622 19x0.302 13.5 177 2.743 144 124 1N22SE 600 TFE 0.0305 7x0.0159 6.7 46 0.108 94 80 6.52 316 0.775 7x0.404 ∗∗ 22.0 151 2.743 140 119 ∗ The armor wires are high tensile, Galvanized Extra Improved Plow Steel (GEIPS), and coated with anti-corrosion compound for protection during shipping and storing. Wires are preformed and cables are post tensioned. ∗ Core assembly – Copper strand consists of a total of nineteen wires. Conductor resistance is...